DC fast charger with battery storage.
Up to 720 kW per cluster from a 100 A service.
Battery buffered DC fast charging puts each DC fast charger on battery storage: five DC fast charger families (Gale, Storm, Tempest, Cyclone, Hurricane) clustered around a Draco ESS hub on the XEYAR shared DC bus. 30 kW to 720 kW per cluster, 2 to 4 dispensers per cluster (custom with Hurricane), typically with no transformer upgrade. Storage rated −40 °C to +65 °C, a flat grid draw that keeps peak demand low, free shipping anywhere in Canada and a $0 KW Energy CMS subscription on KW Energy chargers. VPP-ready hardware; grid-service programs planned for 2027.
DC fast charger families for buffered clusters. One shared DC bus.
Each family targets a specific deployment scenario, from entry-tier workplace DC fast charging to 720 kW highway hubs. All clustered on the XEYAR shared DC bus. Download the family spec sheet or request a configured quote.
Gale
EntryEntry DCFC family. 30 kW or 40 kW per dispenser, 1 to 8 ports per cluster. Right-sized for workplaces, fleet starter deployments, and small-commercial sites that want DC speed without Storm-tier capex.
- Power / dispenser
- 30 or 40 kW
- Ports / cluster
- 2 or 4
- Connectors
- CCS1, built-in NACS cable
- Use case
- Workplace · small comm.
Storm
WorkhorseWorkhorse DCFC family. 120, 180, 240, or 360 kW per dispenser. Built for highway corridor deployments. Liquid-cooled cables at 240 kW and above. The default choice for most commercial DCFC sites.
- Power / dispenser
- 120–360 kW
- Ports / cluster
- 2
- Connectors
- CCS1, built-in NACS cable
- Use case
- Corridor · fleet
Tempest
Ultra-fastUltra-fast urban DCFC. 240 kW or 360 kW per dispenser with a focus on urban form-factor, smaller footprint than Storm with comparable output. Liquid-cooled cables. Premium materials and a 42-inch advertising display.
- Power / dispenser
- 240 or 360 kW
- Ports / cluster
- 2
- Connectors
- CCS1, built-in NACS cable
- Use case
- Urban · premium retail
Cyclone
HubHigh-power HPC hub. One Draco ESS cabinet feeds four dispensers for 240, 360, 480, or 720 kW total cluster output. Highway hubs, fleet depots, HD truck charging. Designed to run on a 100 A service, depending on the site.
- Cluster total
- 240 / 360 / 480 / 720 kW
- Dispensers
- 4 per cluster
- Connectors
- CCS1, built-in NACS cable
- Use case
- Highway · depot
Hurricane
CustomIf your site requires a power tier, port count, enclosure form-factor, or grid configuration that the standard families don’t cover, Hurricane is the path. The XEYAR shared DC bus architecture scales from 30 kW to 1 MW+ with the same fundamental design, only the dispensers and battery sizing change. Engineering NRE quoted per project.
Battery buffered DC fast clusters. One quote away.
Browse all DC cluster SKU configurations on the main Battery Buffered page, or download the DC Cluster Overview PDF for the full architecture story plus technical specifications.
XEYAR battery storage certified to UL 9540, UL 9540A, UL 810A, IEC 62619 and CSA. Chargers cETLus certified (UL 2202 DC, UL 2594 and CSA C22.2 No. 280 Level 2).
Battery buffered DC fast charging. Common questions.
Service capacity, power, peak demand and the Ontario Global Adjustment, connectors, warranty and lead time for buffered DC fast clusters in Canada.
Can I install DC fast charging without a transformer upgrade?
In most cases, yes. A battery buffered DC fast cluster is designed to run on a 100 A, 3-phase 480 V service (83.1 kW continuous), sized per site for 600 V services. The Draco ESS stores energy between sessions and covers the peaks, so the grid never has to supply the full charger power. A site assessment confirms your service and electricity rate.
How much power can a battery buffered DC fast cluster deliver?
From 30 kW to 720 kW per cluster, with 2 to 4 dispensers per cluster (custom with Hurricane). A Cyclone hub feeds four dispensers from one cabinet, up to 720 kW total. Chargers deliver full power while the buffer has charge, and the grid recharges it between sessions.
Will a buffered DC cluster lower demand charges and the Ontario Global Adjustment?
It keeps the peak low. Most Canadian commercial rates bill peak demand (kW or kVA) each month, and a buffered cluster draws a flat load of about 83.1 kW from the grid while the battery covers the charging peaks, instead of a peak equal to every charger at full power. In Ontario, Class A customers pay the Global Adjustment based on their demand during the province’s peak hours, so a flat, capped grid draw helps; Class B customers pay it per kWh. Your site assessment models your actual rate.
What happens when many cars charge at once?
The battery is sized to the site’s port count and use profile, so it covers the expected peaks. KW Energy load management, the dynamic load management layer in KW Energy CMS, is designed to hold at least 50% of nameplate power on every active port. For high-turnover sites, see our guide to gas station DC fast charging.
Which connectors do battery buffered DC fast chargers include?
Every DC fast dispenser has CCS1 and a built-in NACS cable. Standalone units are on our DC fast chargers page.
What warranty and certifications cover a DC fast cluster?
The charger hardware carries a 2-year manufacturer warranty, in addition to your statutory rights, and the XEYAR battery carries a 10-year warranty. Charger warranty extends to 5 years (2 + 3) or 10 years (2 + 8) in total, sold separately, and charger hardware is backed by a 97% uptime SLA.
XEYAR battery storage certified to UL 9540, UL 9540A, UL 810A, IEC 62619 and CSA. Chargers cETLus certified (UL 2202 DC, UL 2594 and CSA C22.2 No. 280 Level 2).
How long does a buffered DC fast cluster take to deliver?
Lead time is 60 to 90 days from order, with free shipping anywhere in Canada; Cyclone 720 hubs with a cabinet and dispensers take longer. Fleet operators can size the cluster with our guide to fleet depot charging.