Battery buffered EV chargers.
Up to 720 kW per cluster from a 100 A service.
Battery buffered EV chargers built on the patent-pending XEYAR shared DC-bus architecture, with storage rated −40 °C to +65 °C for Canadian winters. Add high-power EV charging to an existing 100 A service, typically with no transformer upgrade and no long wait for your local utility (your site assessment confirms it). A flat grid draw also keeps the peak demand on your bill low. VPP-ready hardware ships today; grid-service programs are planned for 2027.
How a battery buffered EV charger works: grid plus battery, not grid versus battery.
The patent-pending XEYAR design uses a shared DC bus where grid input and battery discharge are simultaneous and additive, not sequential. That single architectural choice is why a 100 A service can drive up to 720 kW of EV charging per cluster, typically without a transformer upgrade.
Grid → DC Bus
A 100 A standard service feeds the bidirectional PCS, which converts AC to DC for the shared bus. 24 kW for L2 systems · 83.1 kW for DCFC (3-phase 480 V; sized per site for 208 V or 600 V services), flat, continuous, never spiked.
Same PCS regardless of battery chemistry.
Draco Hub on the Bus
Squall-48 sits on the DC bus and absorbs / releases on demand. Three storage tiers: Na-ion 5C (symmetric, 20K cycles, cost-optimized), SuperCap 3C (symmetric, 500K+ cycles, ultra-long life), and a 1C/2C outdoor cabinet for clusters above 150 kWh. Selected per installation.
Why 5C? Above 5C, the 83.1 kW grid limits the charge side, higher C-rates buy nothing. 5C is the engineered ceiling.
DC Bus → Chargers
Charger power = grid + battery simultaneously. KW Energy CMS is designed to hold at least 50% of nameplate per active port, with KW Energy load management, the dynamic load management layer in KW Energy CMS, designed for EVEMS load-management designs under CEC Rule 8-106, as your electrician and inspector confirm. The battery itself is run by its own battery management system (BMS).
OCPP 1.6, 2.0.1 ready.
Modular Battery-Buffered Clustered EV Charging System
The shared DC-bus architecture, energy management algorithms, multi-port distribution logic, and battery sizing methodology are covered by the XEYAR patent application (Patent Pending, USPTO + CIPO). Engineered with XEYAR Technologies, our battery technology partner.
Typically no transformer upgrade
Designed to run on an existing 100 A service, so most sites skip the major utility upgrade and the long construction queue. Your site assessment confirms it.
VPP-ready hardware today
Bidirectional PCS and Draco ESS are designed for grid export. Grid-service programs are planned for 2027, with no hardware swap required.
At least 50% per active port
KW Energy load management is designed to hold at least half of nameplate power on every active port.
Three storage tiers
Draco supports Na-ion 5C (cost-optimized), SuperCap 3C (ultra-long life), and a 1C/2C outdoor cabinet for large-capacity sites.
Up to 720 kW total
Full-power L2 or DC Fast on a service that traditionally couldn’t support it. Cyclone 720 hub configuration.
Lower thermal-runaway risk
XEYAR battery storage certified to UL 9540, UL 9540A, UL 810A, IEC 62619 and CSA. Chargers cETLus certified (UL 2202 DC, UL 2594 and CSA C22.2 No. 280 Level 2). Na-ion and SuperCap storage carry far lower thermal-runaway risk than lithium-ion, which simplifies siting at indoor, condo and strata sites. Your inspector approves each installation.
−40 °C to +65 °C battery storage
The XEYAR storage is rated from a Canadian prairie winter to summer heat, with no HVAC required. Keeps charging below 0 °C, where many lithium systems restrict it.
Free shipping
Free shipping anywhere in Canada, with no duties or customs fees at delivery. Clusters ship in 60 to 90 days.
Battery buffered Level 2 and DC fast charging. Two power classes.
Buffered Level 2 for overnight condo and strata, workplace, and fleet-depot charging. Buffered DC Fast for high-turnover and corridor sites. Both built on the XEYAR shared DC bus.
Buffered L2 Cluster
48 A or 80 A chargers (Gust, Gust-48) clustered with a Draco ESS hub on a shared DC bus. 8 to 20 ports per cluster, all running off a 100 A standard service.
GUST48-B50N-12C = Gust 48 A · 50 kWh Na-ion · 12-port cluster
Buffered DC Cluster
Full-power DC fast charging, 30 kW to 720 kW per cluster, on a 100 A standard service. Gale, Storm, Tempest, Cyclone and Hurricane families, all clustered on the XEYAR shared DC bus.
TEMPEST240-B150N-2C = Tempest 240 kW · 150 kWh Na-ion · 2-port cluster
Battery buffered cluster models. Sized to your site.
Filter by family type. Battery sizes shown are our strategic defaults per port count, every cluster is custom-sized to your site’s exact load profile, port count, and operating environment.
Ready-to-order XEYAR battery-buffered DC chargers (240 kW, 360 kW and 360 kW liquid-cooled) are in our store: see XEYAR from . Cluster configurations below are quoted per site, priced in CAD. Clusters ship in 60 to 90 days, free anywhere in Canada.
Gust-48 48 · 8-Port Cluster
Gust 48 · 12-Port Cluster
Squall-48 48 · 16-Port Cluster
Squall 80 · 20-Port Cluster
Gale 30 · 2-Port Cluster
Storm 120 · 2-Port Cluster
Storm 240 · 2-Port Cluster
Storm 360 · 2-Port Cluster
Tempest 240 · 2-Port Cluster
Cyclone 240 · 4 Dispensers
Cyclone 480 · 4 Dispensers
Cyclone 720 · 4 Dispensers
12 featured configurations shown. Need a different power tier or port count? Talk to engineering →
VPP-ready hardware. Grid-service programs are planned for 2027.
Every battery buffered EV charger cluster ships with a bidirectional power conversion system and Draco ESS designed for grid export. Grid-service (virtual power plant) programs are not available yet. They are planned for 2027, and the hardware you install today will not need a swap to join them.
A buffered charger
The battery covers charging peaks, so high-power charging runs on the service you already have, typically with no transformer upgrade.
Ready for export
Bidirectional power conversion and battery storage designed for grid export, with KW Energy load management managing the chargers and the battery run by its own BMS.
Grid-service programs
When programs launch, eligibility and any payments will depend on your utility or provincial grid operator, the program rules and how the battery is used.
We do not quote VPP revenue today. Your quote covers charging hardware, storage, installation planning and KW Energy CMS, sized for your site.
Get a battery-buffered quoteBattery buffered reference designs. Engineered scenarios.
Four representative site profiles where battery-buffered clusters can beat conventional charging on cost, time and feasibility. Your actual site is sized by our engineering team, request a site assessment →
120-unit condo, 12 ports, 100 A service.
200-employee office, 20 ports, VPP-ready.
80-van delivery hub, overnight, 100 A grid.
Cyclone 720, 4 dispensers, 100 A service.
Battery buffered vs conventional EV charging. Same site, different architecture.
Reference 12-port Gust 48 A workplace deployment. What each path actually requires, in time, infrastructure, and recurring cost structure.
| Metric | Conventional Non-Buffered | XEYAR GUST48-B50N-12C Winner |
|---|---|---|
| Required Service | 800 A upgrade | 100 A existing |
| Utility Upgrade | Required · transformer build | Typically none |
| Time to Install | 6–9 months (utility queue) | 60–90 days lead time |
| Indoor / MURB Siting | Lithium storage rules & suppression | Lower thermal-runaway risk |
| Operating Range | Varies by chemistry | −40 °C to +65 °C |
| Peak demand on the bill | Up to about 138 kW when all 12 ports run | Grid draw capped near 24 kW |
| Shipping | Varies by supplier | Free anywhere in Canada, no duties at delivery |
| Grid services (VPP) | Not possible | VPP-ready · programs planned 2027 |
| CMS Subscription | Vendor subscription per port | $0 KW Energy CMS subscription on KW Energy chargers |
| Architecture Verdict | Utility-dependent · high recurring cost | Grid-light · VPP-ready · lower OPEX |
XEYAR battery storage certified to UL 9540, UL 9540A, UL 810A, IEC 62619 and CSA. Chargers cETLus certified (UL 2202 DC, UL 2594 and CSA C22.2 No. 280 Level 2).
EV charging without a transformer upgrade. Keep your 100 A service.
Battery buffered EV charger questions. Straight answers.
Battery buffered EV charger architecture, demand charges, inspection, winter performance, VPP roadmap, warranty and deployment time: the answers Canadian engineers and procurement managers ask first.
What is a battery buffered EV charger, and how is it different from a regular DC fast charger?
A battery buffered EV charger includes an on-site energy storage system that sits between the grid and the chargers. Instead of pulling all its power straight from the grid (which needs a much larger electrical service), the system stores energy in the buffer and releases it when EVs are charging.
That lets you deliver high charging power on a small grid connection. A regular 240 kW DC fast charger needs a 240 kW grid connection. A battery-buffered Tempest 240 cluster delivers 240 kW per port from a 100 A standard service while the buffer has charge, because the storage covers the peaks and the grid recharges it between sessions. For a plain-language walkthrough, read EV charging without panel upgrade work.
Do I really not need a utility transformer upgrade?
In most cases, no transformer upgrade is required. Battery-buffered clusters are designed to run on a standard 100 A service (24 kW continuous for Level 2 systems, 83.1 kW for DC fast systems on 3-phase 480 V, sized per site for 208 V or 600 V services). The Draco ESS covers the difference between grid input and charger demand.
This typically avoids the cost of a major transformer upgrade and the long wait for construction by your local utility. We recommend a site assessment to confirm your existing service, panel headroom and electricity rate. Where software alone is enough, dynamic load management may be the simpler option.
How does a battery-buffered cluster affect demand charges and the Ontario Global Adjustment?
Most Canadian commercial electricity rates bill peak demand (kW or kVA) each month. A buffered cluster draws a flat load from the grid (about 24 kW for Level 2 clusters, 83.1 kW for DC clusters) while the battery covers the charging peaks, so the peak demand on your bill stays close to that flat draw instead of the sum of every charger.
In Ontario, the Global Adjustment is a large part of the commercial bill. Class B customers pay it per kWh, and Class A customers pay it based on their demand during the province’s peak hours, where a flat, capped grid draw helps. Your site assessment models your actual rate and customer class.
Sodium-ion or supercapacitor: which battery chemistry should I choose?
Both chemistries sit on the same shared DC bus and power conversion system. Sodium-ion (5C, about 20,000 cycles) is the cost-optimized choice for most sites. Supercapacitor (3C, 500,000+ cycles) suits sites with many short, high-power sessions where cycle life matters most. Clusters above 150 kWh use a 1C/2C outdoor cabinet. Our engineers select the chemistry for each installation.
XEYAR battery storage certified to UL 9540, UL 9540A, UL 810A, IEC 62619 and CSA. Chargers cETLus certified (UL 2202 DC, UL 2594 and CSA C22.2 No. 280 Level 2).
Will an electrical inspector approve a battery-buffered installation?
Under the Canadian Electrical Code, Rule 8-106 lets the calculated load be reduced when an EV energy management system (EVEMS) controls the chargers. KW Energy load management, the dynamic load management layer in KW Energy CMS, manages charger power; your electrician confirms how the design meets Rule 8-106, and your provincial inspector (ESA in Ontario, Technical Safety BC, RBQ / CMEQ rules in Quebec) approves each installation.
XEYAR battery storage certified to UL 9540, UL 9540A, UL 810A, IEC 62619 and CSA. Chargers cETLus certified (UL 2202 DC, UL 2594 and CSA C22.2 No. 280 Level 2).
Sodium-ion and supercapacitor storage carry far lower thermal-runaway risk than lithium-ion, which simplifies siting at condos, strata and other multi-unit buildings. Energy-storage requirements in the building and fire codes your province adopts still apply site by site, and we provide the documentation package your engineer and inspector need.
Do battery-buffered clusters work in a Canadian winter?
Yes. XEYAR storage is rated −40 °C to +65 °C with no HVAC required, and it keeps charging below 0 °C, where many lithium systems restrict it. The KW Energy chargers on the cluster are rated −30 °C to +50 °C.
How long does it take from order to commissioning?
Lead time for battery-buffered clusters is 60 to 90 days from order, depending on configuration. Level 2 clusters are at the shorter end; DC clusters, especially Cyclone 720 hubs with a cabinet and dispensers, take longer.
The big time saving is not waiting for utility infrastructure: a conventional 12-port Level 2 site often needs a transformer or service upgrade that can take 6 to 9 months. The equivalent GUST48-B50N-12C buffered cluster runs on the existing 100 A service. See the EV charger installation timeline for permits and utility steps.
What warranty covers a battery-buffered cluster?
The charger hardware carries a 2-year manufacturer warranty, in addition to your statutory rights, and the XEYAR battery carries a 10-year warranty. Charger warranty extends to 5 years (2 + 3) or 10 years (2 + 8) in total, sold separately, and charger hardware is backed by a 97% uptime SLA; ask for terms in your quote.
Can a battery-buffered cluster provide grid services (VPP)?
Every battery-buffered cluster ships VPP-ready hardware: the bidirectional power conversion system and Draco ESS are built for grid export and grid services.
Grid-service programs are planned for 2027 and are not available yet, so today the hardware works as a buffered charger only, with no hardware swap needed later. We do not quote VPP revenue.
Is shipping free in Canada?
Yes. Shipping is free anywhere in Canada, with no duties or customs fees at delivery. Clusters ship in 60 to 90 days. Your quote lists anything outside standard freight, such as cranes or site rigging for large cabinets.